Excellence, dedication, and experience are important qualities for a fluorine expert.

Specialized Team of Fluorine Chemical Experts.

about
about

We mainly deliver services to the following customers:

  • Investors who seeking to construct a production facility for chemicals based on fluorine.

  • Facilities that possess waste acid containing fluorine and aiming to recycle it.

  • Facilities with wastewater containing fluorine, looking to purify or treat it.

  • Facilities that possess tail gas containing fluorine and aiming to purify or treat it.

The process design & production equipment we provide has the following technical characteristics

  • Technical feature sub-item Technical feature description

  • 1. Intrinsically safe

  • a. Select process equipment, pipelines, valves and sensors in strict accordance with process parameters; and give priority to new equipment such as microchannel reactors, microchannel mixers, and microchannel rectifiers;

  • b. Through the miniaturization, modularization, precision, and intelligence of chemical equipment, the intrinsic safety of chemical production lines is realized.

  • c. Integrate the current advanced technology into the process design in a timely manner, for example: the automatic control unit of material ratio can ensure the rationality of the ratio of the reaction system; the self-learning function of the control system can improve the intelligence level of the control device.

  • d. An emergency response system is designed for each production line. In the event of equipment failure or man-made accidents, the emergency response system will ensure that the production line will not have safety and environmental accidents.

  • e. Detailed, illustrated "Operation Manual".

  • 2. Turning Waste Into Treasure

  • Our Technology Is Dedicated To Turning Waste Into Treasure, Which Can Re-Use Fluorine-Containing Waste In Many Industries And Transform It Into Industrial Products. In The Process Design, This Principle Is Always Implemented; Therefore, We Will Utilize The Waste Materials And Waste Heat Energy In The Process To Achieve The Excellent Effect Of Energy Saving And Emission Reduction.

  • 3. Reasonable Investment

  • Our Designs Always Start From The Process Parameters, Don't Overuse Raw Materials, Don't Overuse Expensive Equipment, And Consider How To Reduce Investment Costs From The Perspective Of Investors; The Production Line We Design May Reduce Investment Costs By 20% Compared With Similar Production Lines Above.

  • 4. Intelligent Devices And On-Site Unmanned

  • Using Advanced Intelligent Control System, Multiple Types Of Sensors And On-Site High-Definition Video, Laying The Foundation For The Realization Of On-Site Unmanned Operation Of The Production Line. In Addition To Unloading Raw Materials And Product Handling That Require Manual Assistance, All Process Operations And Emergency Switching Operations Are Completed In The Control Room; And Production Line Patrol Personnel Can Be Eliminated.

  • 5. Green Process

  • Our Process Design Is At The Best Level Of Current Technology To Ensure That The Process Is Green, Environmentally Friendly And Safe.

  • 6. Reduce carbon emission

  • We have adopted many energy-saving and emission-reducing technologies and processes, and often use waste as raw materials, making substantial contributions to global carbon emission reduction.

  • 7. Comprehensive array of sensor configurations and automated systems

  • Pressure, temperature, flow rate, liquid level, pH value and other parameters are all transmitted to the DCS control system in real time through sensors. The advanced DCS control system enables production management, process control, multi-point interlocking and over-limit alarm to be carried out seamlessly throughout the entire process. Process operation can be completed with a simple click of a mouse in the control room. A variety of automatic processing and alarm functions have been established, with protective measures such as automatic alarms, switches, circuit breakers, and shutdowns adopted for various abnormal situations. Meanwhile, a manual auxiliary intervention (emergency) operating system is also available to ensure that the system can be processed automatically or manually. The key process operating points are equipped with automatic adjustment and interlocking control to minimize the possibility of human error.

  • 8. Data record

  • All operating parameters and operating process are automatically recorded by the computer, which can monitor the process at any time, analyze the cause, and modify the parameters to make the system run in the best state. All data can be output to display devices, printing devices, computer hosts, etc.

  • 9. Camera monitoring

  • All-round high-definition camera monitoring, you can monitor everything in the workshop in the control room. It can also read on-site instrument display values, equipment operating status, etc.; in the control room, it can monitor the entire production process and the operation of multiple important equipment, reduce (or cancel) the number of workshop inspections, and reduce the safety risk during manual inspections.

  • 10. Open and prepare

  • Both pump equipment and fan equipment adopt 1 on 1 standby or 2 on 1 standby, which can be switched automatically to ensure that the production process does not stop.

  • 11. Pump valve box

  • Pump equipment and valves are installed in a closed pump valve box, and the box is in a negative pressure state; a leakage alarm is installed at the bottom of the box. Even if the pump equipment or valve leaks, it will not cause harm to personnel and the surrounding environment; the alarm can promptly remind the staff to deal with the leakage.

  • 12. Double casing

  • The acid liquid delivery pipe adopts a double-tube structure, the inner pipe is an acid liquid delivery pipe, the outer pipe is a transparent safety pipe, and a liquid leakage alarm is installed in the outer pipe. When a leakage failure occurs in the delivery pipe, it will not harm the person and the surrounding environment, and the alarm can promptly remind the staff to deal with the leakage failure.

  • 13. Shock protection

  • Each rotating equipment is equipped with a protective safety cover; all equipment with motors is equipped with an anti-shock mechanism to reduce shock and noise. Fan equipment is equipped with a soundproof room to reduce the impact of noise on the surrounding environment.

  • 14. Space optimization

  • The equipment layout adopts an optimized design, and in a limited space, it is ensured that sufficient operating space is left for equipment maintenance and overhaul, which is convenient for equipment maintenance and operation.

  • 15. Corrosion resistant material

  • Various types of equipment and their pipelines are made of corrosion-resistant materials or corrosion-resistant treatments that are compatible with materials and process parameters. These materials include: Hastelloy, Monel, CS+C276, CS+PE, CS+PTFE, CS+PVDF, SiC, fluorine-impregnated graphite, etc.

  • 16. Tank leak protection

  • In the storage tank area of dangerous materials, two detection methods, such as liquid leakage alarm and toxic and harmful gas detector, are installed to ensure timely detection of acid leakage.

  • 17. "Empty The Storage Tank" System

  • For multi-tank units, an "empty tank" system is set up to allow for emptying and disposal in the event of a tank leak.

  • 18. Flange

  • All flange connections are equipped with "PP transparent flange sleeves"; even if leakage occurs at the flange seal, it will not cause harm to personnel and the surrounding environment.

  • 19. Grounding and Flame Retardant

  • According to the characteristics of the raw materials and products of the device, electrical equipment is selected according to relevant laws and regulations; electrostatic grounding measures are taken according to the regulations; all cables and cable trays are flame-retardant or flame-retardant.

  • 20. Guardrail and anti-slip

  • Equipment operating platforms, stairs, aisles, roofs, etc. are equipped with guardrails and anti-slip treatment.

  • 21. Accident shower and first aid ointment

  • Washing equipment such as eye washers and showers are installed in the workshop where most likely to be exposed to toxic and corrosive materials, so that they can be cleaned nearby in time when an accident occurs. The operation room is equipped with a special ointment for first aid of hydrofluoric acid burns; once the skin comes into contact with toxic or corrosive materials, it can be washed immediately and the ointment can be applied.

  • 22. Clearly marked

  • Through color-coded blocks and pasted signs, pipelines, grounds, safety passages, etc. can be clearly distinguished; all signs comply with the provisions of the national standard.

  • 23. Gas leak protection

  • There are protective isolation facilities and toxic and harmful gas detectors for possible leakage points. Air extraction devices are installed at locations where peculiar smell may occur, and the extracted gas enters the exhaust gas absorption device. When a leakage accident occurs, the accident emergency absorption system will be activated, and all the leaked gas will enter the accident emergency absorption system for intensive disposal.

  • 24. On-Site Training

  • We will assist the owner to effectively train the staff, so that each operator can master the operational skills and emergency response skills.

  • 25. Detailed Operation Manual

  • In the "Operation Manual", there are detailed operating procedures and methods, trial production debugging procedures, etc.; and provide "abnormal situation handling methods" and "safety emergency handling plan" and other contents. In the "Operation Manual", the code of conduct for safe production is proposed, which can be used as the owner's safety production rules and regulations.